Machine-Room-Less
Small Machine Room
Passenger elevator

EKCNE elevator

Reduction in machine room area The machine room dimensions match the shaft, with an area only 40%-60% of a traditional machine room

The permanent magnet synchronous (PMSM) drive machine is embedded at the top of the elevator shaft (distance from the top floor ≤3.5m), completely

Permanent Magnet Synchronous Gearless Drive Technology

Energy Efficiency

Using rare-earth permanent magnet materials (NdFeB), achieving 40%-60% energy savings compared to traditional asynchronous motors; IP54 protection grade ensures stable energy efficiency.

Run Mute

Gearless design eliminates mechanical friction noise, operating noise ≤45dB, compliant with ISO 4871 acoustic standards, suitable for high-end hotels, office buildings, and medical facilities.

High-Efficiency Power

Rated speed 0.5-2.5m/s, suitable for diverse speed requirements in high-rise residential and commercial buildings.

The Latest Group Control Solution

Precise control enables precise movements, shortens waiting times and saves energy, and enables advanced group management (ZAI)

Optimize allocation as a whole

Predict the near-term lobby (landing) call and reduce the waiting time for elevator allocation

Dynamic rule settings optimize the system

By simulating the Rule Setup, the most appropriate car assignment is selected

Energy-saving operation - distribution control

Minimizes the operating distance of the elevator and reduces energy consumption throughout the day

Neural network fuzzy theory

The performance results of the cases in the simulation and their rule settings

Compact Structure, Simplified Maintenance 

Modular design with integrated bent guide rail and flat permanent magnet motor reduces installation space by 30%.

Lubrication-free mechanism lowers annual maintenance costs to 40% of traditional models.

Adopt Permanent Magnet Synchronous Door Operator Technology

Energy Efficiency

Using rare-earth permanent magnet materials (NdFeB), achieving 40%-60% energy savings compared to traditional asynchronous motors; IP54 protection grade ensures stable energy efficiency.

Quiet Operation, Enhanced Adaptability
to High-End Scenarios

Gearless design + VVVF frequency control technology achieves operating noise ≤45dB, lower than standard door operators (55-60dB). ·Certified to ISO 4871 for acoustics, with door acceleration fluctuation ≤5%, eliminating operational jerkiness.

Technology

Energy Conservation

Decoration

Safe

Environmental Protection

Energy Saving

LED energy-saving lighting

The use of LED technology for the lighting of car roofs and landing direction lights can significantly reduce the amount of electricity consumed by elevator lighting. The use of LED lighting technology reduces the frequency of light source replacement, reduces maintenance costs, and reduces the generation of harmful substances such as mercury.

Energy Feedback Technology (PCNV)

Yongtongli elevator energy feedback technology will be the elevator light load up, heavy load down, the renewable energy generated by the most careful processing, to obtain “green electricity” to the grid, not only to reduce the elevator energy consumption, but also to supply the same power system of other electrical equipment.

Fans and lights are automatically turned off

Automatic Fan Shutdown (CFO-A): After the elevator is in undirected standby for a certain period of time, the ventilation device automatically shuts off to save energy.

Variable Speed Elevator System VSE

The elevator speed varies depending on the number
of passengers to shorten the waiting and boarding time

The “Variable Speed Elevator System” is an optional system that uses the balance of the car and counterweight to increase the operating speed according to changes in the number of passengers. Compared with conventional elevators that operate at rated speeds, the VSE system is a new elevator system designed to cope with the undesirable conveyance effects of long waiting times and slow operation speeds by reducing the waiting time and riding time of passengers and making the elevator run more efficiently in buildings.

Variable Speed Elevator System VSE

The elevator speed varies depending on the number
of passengers to shorten the waiting and boarding time

The “Variable Speed Elevator System” is an optional system that uses the balance of the car and counterweight to increase the operating speed according to changes in the number of passengers. Compared with conventional elevators that operate at rated speeds, the VSE system is a new elevator system designed to cope with the undesirable conveyance effects of long waiting times and slow operation speeds by reducing the waiting time and riding time of passengers and making the elevator run more efficiently in buildings.

Elevator Intelligent
Interactive System(Optional)

Face
Recognition Terminals(Optional)

When the new building is designed, the shaft buffer limit is reduced to save construction costs

IC Card Reader
Identification Terminal (Optional)

Contactless card reader for swiping the card to take the elevator to improve building safety.

Fingerprint
Recognition Terminal (Optional)

Fingerprint encrypted storage, data security The latest optical recognition module, ultra-high recognition rate

Indoor and Outdoor
Call Recognition (Optional)

Fashionable man-machine interface, information visual operation

User-friendly Design

Contat EKCNE